Estimator works in your browser

Airflow and height estimator

Two quick estimates from figures you enter: how much air has to pass through to carry a heat load away, and how much rack space a chassis gives before you subtract what sits under the cooler. Nothing you type leaves this page.

A Airflow needed

Air needed for the heat you enter

W The heat given off in the air path you are sizing. For one CPU, its TDP is a common starting figure; add other parts in the same air path if you know them. Use a decimal point and omit thousands separators.
A difference, not a temperature. A smaller rise needs more air. Use a decimal point and omit thousands separators.

Enter the heat and the rise to see the estimate. Nothing is pre-filled: the greyed numbers are only examples.

B Height envelope

Rack space left for a cooler

Enter a chassis height in U to see the estimate. Nothing is pre-filled: the greyed numbers are only examples.

How the estimates work

Airflow needed

airflow (m³/s) = heat (W) ÷ (ρ × cp × ΔT)
CFM = m³/s × 60 ÷ 0.028316846592  ≈ 1.76 × W ÷ ΔT (°C)
  • ρ = 1.2 kg/m³ and cp = 1005 J/(kg·K): the density of dry air and its specific heat at constant pressure, at the usual room-temperature, sea-level convention (101.325 kPa). The sensible heat balance is heat = mass flow × cp × ΔT, and mass flow = ρ × volume flow.
  • ΔT is how much warmer the air leaves than it arrives. One °C of rise is one K. A rise entered in °F is converted with × 5/9 (a difference, so no 32 offset).
  • Unit conversions: 1 ft = 0.3048 m exactly, so 1 ft³ = 0.028316846592 m³ and 1 m³/s ≈ 2118.88 CFM (a rounded figure). One minute is 60 s, one hour is 3600 s and 1 L = 0.001 m³.
  • It assumes all the heat goes into the air stream and the air is evenly mixed. Thinner air at altitude carries less heat per cubic metre, so it needs more volume than this.
  • The result is bulk airflow through the air path that carries the heat you entered. If you enter whole-server heat, it is the air for the whole server, not only the air that crosses the heatsink fins. Installed fan flow depends on the fan curve and the resistance of the system (fins, filters, drive cages), so a fan's free-air rating is not what you will get.

Height envelope

estimated room (mm) = U × 44.45 mm − total space lost
inches = mm ÷ 25.4
  • 1U = 1.75 in = 44.45 mm, the rack unit of the EIA-310 rack standard; 1 in = 25.4 mm exactly.
  • That is the rack space, not the chassis. A real 1U chassis is usually a little under 44.45 mm tall so units do not rub. Total space lost is everything you subtract: the chassis floor and lid, the mounting stack (standoffs, board, socket), and any obstruction above or below the cooler.
  • The comparison with a cooler height is plain subtraction. Use the chassis maker's stated CPU cooler clearance when there is one; it already includes what this estimate cannot see, such as a crossbar or a power supply over the socket.

Both results are estimates for planning, not a fit or cooling guarantee. For the height limits common in 2U, 3U and 4U chassis, see the guides.

Sources for the constants